Our laser
For
refractive disorders correction, our workplace has the most advanced facility in
the Czech Republic; all of the devices dispose of American FDA certificate. For
the laser corrections, we are using the laser Zeiss MEL 80CRS TwinLine, model
2007, rightfully considered as the world´s technological peak product. The
laser is utilizing wavefront technology. Due to that, using the laser, we may
precisely correct, except short – sightedness, long-sightedness, astigmatizm
and presbyopia, also various cornea irregularities including high plus
astigmatizm (up to +8 cylinders) that is often technologically impossible with
other devices.
The laser main merits:
High speed
- The operation is extremely fast, one dioptry correction takes less than
3 seconds so the whole operation is less stressing to the patient
- Cornea is exposed to the beam for a significantly shorter time so it is drying
much less and healing much faster
- Very fast return of sight acuity after the operation
Extremely small spot diameter (0.7 mm) and Gaussian beam profile
- Highly precise cornea treatment
- Perfectly smooth cornea surface due to unique distribution of individual spots
Thermally optimized healing profiles
- Unique distribution of individual points provides the cornea optimal protection against overheating also on a high speed
Prolate ablation profile
- Newly developed aspheric profile improves twilight sight quality
- Contrast improvement
Full-value Customized Ablation – CRS Master
- On contrary to the standard mode optimized only according to cornea aberrations (curvature deviations), the customized ablation takes into account an every patient individual data.
- CRS-Master is the system connecting wavefront diagnostics with cornea topography (not offered by other devices), so all the data are evaluated by the single device and not by their combination (e.g. wavefront diagnostics + Pentacam).
- During the operation planning, also a patient age can be taken into account as well as the micro-ceratom type (in LASIK and EPI-LASIK operations), flap thickness and individual wishes of an every patient.
Aberrometer Wasca and topographer ATLAS 995 
- These systems enable removing of previously unsolvable, very complicated optical aberrations and de-centering; due to them, many patients will reach their sight acuity as much as 120%!
- The own investigation takes only 13 miliseconds. Due to that, there may be virtually eliminated inaccuracies given by eye moving within the measurement – a better precision and, also, an improved patient comfort.
- Higher-level aberrations are complex, inhomogeneous distribution of refraction force in the area of pupil that cannot be described by refraction values such as sphere or cylinder. The optical aberrations such as coma and spherical aberrations cannot be detected by conventional methods and are frequently manifested as difficulties such as worsened night vision.

Extremely fast infrared Eyetracker
- During the operation, it is important to have a device recording
small-extent eye movement as fast and as accurate as possible. In CR unique
OcuLign system automatically recognizes pupil and, furthermore, using so called
iris-registration, is controlling eye position and so called torsion (wheels)
according to blood vessels on both iris and white. The system is as fast as
laser beam so the laser is always in the correct point.
- As the perfect pre-operation diagnostics part, also the device serving to optical pachymetry (patient cornea thickness measurement) is included. The cornea thickness is a key parameter for selection of proper operation method (surface – EPI-LASIK and PRK vs. LASIK).
- The slit lamp enables surgeon control the results immediately after
realization of the operation, directly in chart room
Wavefront diagnostics- during
pre-operation investigation using Wasca device, in only 13 miliseconds we are
perfectly mapping patient iris and small blood vessels on white – the device
will make the wavefront map unique for an every eye.
Eye registration – before the own
operation, the OcuLign system will recognize characteristic features –
reference points of the patient iris and white.
During the operation, the system is
checking even the smallest movement of the patient eye in order to have the
operation exactly as it was planned.
VISANTE OCT 
- As the perfect pre-operation diagnostics part, also the device serving to optical pachymetry (patient cornea thickness measurement) is included. The cornea thickness is a key parameter for selection of proper operation method (surface – EPI-LASIK and PRK vs. LASIK).
**Connected slit lamp
- The slit lamp enables surgeon control the results immediately after realization of the operation, directly in chart room
**As our philosophy, reliability, credibility and awareness of personal responsibility are to be taken into account. **









